Managed Pre-Analysis Module - MPAM - (A&T)
MPAM
Size
Weight
Power Voltage
Power Dissipation
:
:
:
:
1670(W)x1018(D)x1400(H)mm
460kg
AC200V
2kVA
Biochemistry Module - JCA-BM2250LA Type - *1 (JEOL)
JCA-BM2250LA It realizes powerful throughput of 2400 tests/h at Max (with ISE module) and small reaction volume of 60µL by auto dilution function.

Size
Weight
Power Voltage
Power Dissipation
Water Volume
:
:
:
:
:
2135(W)x1070(D)x1157(H)mm
Approx. 820kg
AC100V
3.2kVA
60L/h
To the Top
Biochemistry Module - JCA-BM6050LA Type - *1 (JEOL)
Provides ultratrace photometric assay with the adoption of pre-analytical diluent unit and ultra-thin cuvette, enabling minimum reaction volume of 50µL. In addition to the improved throughput of 600 tests/hr by the ISE unit, this module handles 1,800 tests/hr in clinical chem. + electrolyte analysis.

Size
Weight
Power Voltage
Power Dissipation
Water Volume
:
:
:
:
:
1915(W)x1070(D)x1133(H)mm
Approx. 680kg
AC100V
3.2kVA
60L/h
*1 The Values of Size, Weight, Power Dissipation includes the Connection Module of A&T.
Electrolyte Analyzer Module - EA08M - (A&T)
EA08M Electrolyte assay items, Na, K and Cl are processed in a high speed of 200 samples/hr.
Urine samples can also be measured.

Size
Weight
Power Voltage
Power Dissipation
:
:
:
:
450(W)x630(D)x1255(H)mm
Approx. 55kg
AC100-240V
0.2kVA
Immunology Module - AIA-2000LA - (Tosoh)
AIA-2000LA
Size
Weight
Power Voltage
Power Dissipation
:
:
:
:
1500(W)x1197(D)x1260(H)mm
Approx. 400kg
AC100V
0.7kVA
To the Top
Immunology Module - MI02 - (A&T)
MI02 It Takes Only 11 Min. from Sampling to Report. Throughput is 400 Tests/h at Max.

Size
Weight
Power Voltage
Power Dissipation
Water Volume
:
:
:
:
:
1200(W)x700(D)x1300(H)mm
Approx. 350kg
AC100/200V
1.2kVA
22L/h
Sample Loading Module - SL01 - (A&T)
SL01 Parent Samples are Loaded on the Dedicated 5P Carrier. The Samples are Moved to the 1P Holder and Proceeded to the Pre-Analytical and Analytical Modules. Carrier or Tray (30 Carriers at Maximum) can be Loaded. There are Three Lanes and the STAT Lane is Processed with priority.

Size
Weight
Power Voltage
Power Dissipation
:
:
:
:
920(W)x1274(D)x1400(H)mm
Approx. 280kg
AC200V
0.5kVA
To the Top
Unloading and Sorting Module - US01 - (A&T)
US01 Parent Samples After Aliquot and Daughter Samples after Measurement are collected to the Dedicated 50P Carrier. Enable to Sort / collect Parent-Daughter Samples.

Size
Weight
Power Voltage
Power Dissipation
:
:
:
:
910(W)x1274(D)x1400(H)mm
Approx. 280kg
AC200V
0.3kVA
Buffer Module - BF01 - (A&T)
BF01 Temporarily Stores Pre-Analytical Samples and Sends them Out in Order of Priority. Prevents Sample Congestion and enables Smooth Test Performance.

Size
Weight
Power Voltage
Power Dissipation
:
:
:
:
320(W)x1274(D)x1025(H)mm
Approx. 100kg
AC200V
0.2kVA
To the Top
Conveyer Module - FC01 - (A&T)
FC01 Transfers Samples Between Modules. Transferring of 1P holder with High Speed Feeder Realizes High Efficiency.

FC01-10 Size
Weight
Power Voltage
Power Dissipation
:
:
:
:
1180(W)x309(D)x1025(H)mm
Approx. 80kg
AC200V
0.2kVA
FC01-20 Size
Weight
Power Voltage
Power Dissipation
:
:
:
:
2180(W)x309(D)x1025(H)mm
Approx. 100kg
AC200V
0.2kVA
General Connector Module - GC01 - (A&T)
Connector of Conveyer Module and Analyzer where Sampling is Performed. Stores Minimum Required Samples according to the throughput of Analyzers.
GC01 GC01-S
Size
Weight
Power Voltage
Power Dissipation
:
:
:
:
300(W)x310(D)x463(H)mm
Approx. 15kg
AC200V
0.2kVA

GC01-M
Size
Weight
Power Voltage
Power Dissipation
:
:
:
:
300(W)x460(D)x931(H)mm
Approx. 20kg
AC200V
0.2kVA

GC01-L
Size
Weight
Power Voltage
Power Dissipation
:
:
:
:
300(W)x610(D)x931(H)mm
Approx. 25kg
AC200V
0.2kVA
Traffic Controller - CLINILOG Tc - (A&T)
SM01 It controls the operation of all modules and measurement results, and communicates with the host computer.

Size
Weight
:
:
In the Rack of Option
Power Dissipation : 0.4kVA