Managed Pre-Analysis Module - MPAM - (A&T) |
|
 |
Size
Weight
Power Voltage
Power Dissipation |
:
:
: : |
1670(W)x1018(D)x1400(H)mm
460kg
AC200V
2kVA |
|
|
Biochemistry Module - JCA-BM2250LA Type - *1 (JEOL) |
|
 |
It realizes powerful throughput of 2400 tests/h at Max (with ISE module) and small reaction volume of 60µL by auto dilution function.
Size
Weight
Power Voltage
Power Dissipation
Water Volume |
:
:
:
: : |
2135(W)x1070(D)x1157(H)mm
Approx. 820kg
AC100V
3.2kVA
60L/h |
|
| To the Top |
|
Biochemistry Module - JCA-BM6050LA Type - *1 (JEOL) |
|
Provides ultratrace photometric assay with the adoption of pre-analytical
diluent unit and ultra-thin cuvette, enabling minimum reaction volume of
50µL. In addition to the improved throughput of 600 tests/hr by the
ISE unit, this module handles 1,800 tests/hr in clinical chem. + electrolyte
analysis.
Size
Weight
Power Voltage
Power Dissipation
Water Volume |
:
:
:
: : |
1915(W)x1070(D)x1133(H)mm
Approx. 680kg
AC100V
3.2kVA
60L/h |
|
|
|
*1 The Values of Size, Weight, Power Dissipation includes the Connection
Module of A&T. |
|
|
Electrolyte Analyzer Module - EA08M - (A&T) |
|
 |
Electrolyte assay items, Na, K and Cl are processed in a high speed of 200 samples/hr.
Urine samples can also be measured.
Size Weight
Power Voltage
Power Dissipation |
:
:
: : |
450(W)x630(D)x1255(H)mm Approx. 55kg
AC100-240V
0.2kVA |
|
|
Immunology Module - AIA-2000LA - (Tosoh) |
|
 |
Size
Weight
Power Voltage
Power Dissipation |
:
:
: : |
1500(W)x1197(D)x1260(H)mm
Approx. 400kg
AC100V
0.7kVA |
|
| To the Top |
Immunology Module - MI02 - (A&T) |
|
 |
It Takes Only 11 Min. from Sampling to Report. Throughput is 400 Tests/h
at Max.
Size
Weight Power Voltage
Power Dissipation
Water Volume |
:
:
:
: : |
1200(W)x700(D)x1300(H)mm
Approx. 350kg
AC100/200V
1.2kVA
22L/h |
|
|
Sample Loading Module - SL01 - (A&T) |
|
 |
Parent Samples are Loaded on the Dedicated 5P Carrier. The Samples are Moved to the 1P Holder and Proceeded to the Pre-Analytical and Analytical Modules. Carrier or Tray (30 Carriers at Maximum) can be Loaded. There are Three Lanes and the STAT Lane is Processed with priority.
Size
Weight
Power Voltage
Power Dissipation |
:
:
: : |
920(W)x1274(D)x1400(H)mm
Approx. 280kg
AC200V
0.5kVA |
|
| To the Top |
Unloading and Sorting Module - US01 - (A&T) |
|
 |
Parent Samples After Aliquot and Daughter Samples after Measurement are
collected to the Dedicated 50P Carrier. Enable to Sort / collect Parent-Daughter
Samples.
Size
Weight Power Voltage
Power Dissipation |
:
:
: : |
910(W)x1274(D)x1400(H)mm
Approx. 280kg
AC200V
0.3kVA |
|
|
Buffer Module - BF01 - (A&T) |
|
 |
Temporarily Stores Pre-Analytical Samples and Sends them Out in Order of
Priority. Prevents Sample Congestion and enables Smooth Test Performance.
Size
Weight
Power Voltage
Power Dissipation |
:
:
: : |
320(W)x1274(D)x1025(H)mm
Approx. 100kg
AC200V
0.2kVA |
|
| To the Top |
Conveyer Module - FC01 - (A&T) |
|
 |
Transfers Samples Between Modules. Transferring of 1P holder with High Speed Feeder Realizes High Efficiency.
| FC01-10 |
Size
Weight
Power Voltage
Power Dissipation |
:
:
: : |
1180(W)x309(D)x1025(H)mm
Approx. 80kg AC200V
0.2kVA |
| FC01-20 |
Size
Weight Power Voltage
Power Dissipation |
:
:
: : |
2180(W)x309(D)x1025(H)mm
Approx. 100kg
AC200V
0.2kVA |
|
|
General Connector Module - GC01 - (A&T) |
|
| Connector of Conveyer Module and Analyzer where Sampling is Performed. Stores Minimum Required Samples according to the throughput of Analyzers. |
 |
GC01-S
Size
Weight
Power Voltage
Power Dissipation |
:
:
: : |
300(W)x310(D)x463(H)mm
Approx. 15kg
AC200V
0.2kVA |
GC01-M
Size
Weight
Power Voltage
Power Dissipation |
:
:
:
: |
300(W)x460(D)x931(H)mm
Approx. 20kg
AC200V
0.2kVA |
GC01-L
Size
Weight Power Voltage
Power Dissipation |
:
:
: : |
300(W)x610(D)x931(H)mm
Approx. 25kg AC200V
0.2kVA |
|
|
Traffic Controller - CLINILOG Tc - (A&T) |
|
 |
It controls the operation of all modules and measurement results, and communicates
with the host computer.
Size
Weight |
:
: |
In the Rack of Option |
| Power Dissipation |
: |
0.4kVA |
|